A Smart PDU

Your wish is our command

We offer the broadest range of custom-made PDU models ranging from basic, metered to highly intelligent (outlet monitored and switched), three phase or single phase and ratings of 10A up to 63A. Also we support all worldwide AC voltage and current rates and supply the most options for input plugs (IEC, NEMA etc) and outlet types (including Schuko).

Build-to-order PDUs

These are 5 basic steps you should follow to help you to select and deploy the appropriate rack PDUs for your data center:

1. Find the power inlet location, determine the form factor that best fits the racks (horizontal or vertical) and decide on the required length of the input power cord.

2. Determine the infrastructure voltage and circuits, phase, and amperage for the rack (16A/32A/63A, single phase or three phase).

3. Find out how many devices are in the racks and what type type of plugs are used on the devices in the rack e.g. C14, C20 or Schuko in order to determine the PDU outlet number and types and the total power (kW, kVA) required. Optional: locking outlets.

4. Decide if remote outlet switching is desired and what level of metering is required (no metering, per PDU or per outlet) and if a local display is needed.

5. Figure out if there is a for need for ethernet (IP) access, coloured PDUs or environmental monitoring.


Security 

Our PDUs support the most stringent security protocols in the market in order to prevent unauthorized access (256 bit AES encryption, Radius, SNMPv3, user permissions, SSH, SSL, HTTPS).

Hydraulic-magnetic Circuit Breakers

Our PDUs are equipped with highly reliable hydraulic-magnetic circuit breakers which are not affected by ambient temperature and support delay curves appropriate for IT-equipment. Also our solutions proactively monitor the status of the breakers in order to prevent downtime due to server power supply failure or overloads.

Energy Efficient Latching Relays

Our PDUs are equipped with energy efficient, bi-stable latching relays. These relays consume up to 70% less energy than alternatives, make outlet switching safer and can be configured in such a way that in case of PDU failure the power distribution to the rack is maintained.

Kwh Metering Accuracy

All our PDUs feature +/- 1% billing grade accuracy enabling precise allocation of datacenter expenses.

Full Color Range

Powertek PDUs are available in any RAL-colour. Coloured PDUs make it easier to reduce human errors, identify power feeds and lowering the risk of unplanned downtime. 

Secure Locking Outlets

Powertek intelligent rack PDUs are equipped with lockable outlets preventing powercords from coming unplugged due to human error or vibration.

Residual Current Monitoring Option

By measuring current flowing in the ground wire, our residual current monitoring option reduces the risk of electric shock. PDUs equipped with residual current monitoring dramatically reduce the burden of regulatory auditing.

Cascading Option

In order to save on network ports and manage multiple devices from one IP address we offer the opportunity to daisychain up to 8 PDUs using Cat5/6 cable.

Environmental Monitoring Devices (EMD)

We provide optional all in one sensors with temperature and humidity measurement and 2 additional digital input contacts for connecting for example waterleak-, door position-, airflow-, smoke dtection- or vibration sensors.

Network Protocols

Our PDUs support HTTP(s), SSH, RS-232 (Serial), SNMP v1/v2/v3, SMTP and Modbus

Circuit Breaker Trip Alarming

Our solutions pro-actively monitor the status of the circuit breakers (voltage and current monitoring) and will send you an alert in case a circuit breaker has tripped.

Operating Temperature

Powertek PDUs support a maximum operating temperature of up to 60 degrees Celsius for reliable performance in dense, high heat environments.

 

Interoperability with third party software

If you would like to centrally manage all PDUs in your datacenter this is possible. Our solutions offer the option to communicate the status of rack-level power and environmental information to a third party Datacenter Infrastructure Management (DCIM) solution such as Power IQ.